EVM  PROGRAMMING FOR HYBREX  BX-320

EVM  PROGRAMMING  ITEMEVM  PROGRAMMING  DATA                EXPLANATION
For  op / ext ring duration during
working / closing hrs
SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00]
SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00]
Un-supervisory ringback tone                  
For release after answerSYS _ 5 _ 2 _ [5]ON HOOK
For release w / o waitingSYS _ 5 _ 3 _ [5]ON HOOK
For retrieving call once error toneSYS _ 5 _ 4 _ [1]HOOK FLASH
For retrieving call once on busySYS _ 5 _ 5 _ [1]HOOK FLASH
For retrieving call once no answerSYS _ 5 _ 6 _ [1]HOOK FLASH
For message lamp onSYS _ 5 _ 7 _ [8]Function code + Extn
For message lamp offSYS _ 5 _ 8 _ [8]Function code + Extn
For no-answer identified code
( For Incoming co line )
SYS _ 6 _ 3 _ [ Function code ]Refer to PBX programming
For busy identified code
( For Incoming co line )
SYS _ 6 _ 4 _ [ Function code ]Refer to PBX programming
For code of message lamp onSYS _ 6 _ 6 _ [ 7071 ]Function code of message lamp ON is
7071 ( PBX Default )
For code of message lamp offSYS _ 6 _ 7 _ [ 7072 ]Function code of message lamp OFF is7072 ( PBX Default )
For hook flash timeSYS _ 7 _ 1 _ [By auto detection ]Refer to EVM GUIDE:
How to auto detect hook flash time
For busy tone cycleSYS _ 7 _ 5 _ 1 _ [048]
SYS _ 7 _ 5 _ 2 _ [045]
SYS _ 7 _ 5 _ 3 _ [048]
SYS _ 7 _ 5 _ 4 _ [045]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect busy tone cycle
For ringback tone cycleSYS _ 7 _ 6 _ 1 _ [096]
SYS _ 7 _ 6 _ 2 _ [186]
SYS _ 7 _ 6 _ 3 _ [096]
SYS _ 7 _ 6 _ 4 _ [186]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect ringback tone cycle
Waiting time for ID codeADM _ 5 _ 9908 _ [ 2000 ]Delay 2 sec before detecting ID code
Prefix number of Mailbox ID codeADM _ 5 _ 9920 _ [ Function code ]Refer to PBX programming
Suffix  number of Mailbox ID codeADM _ 5 _ 9921 _ [ Function code ]Refer to PBX programming
For no-answer identified code
( For Internal call )
ADM _ 5 _ 9928 _ [ Function code ]Refer to PBX programming
For busy identified code
( For Internal call )
ADM _ 5 _ 9929 _ [ Function code ]Refer to PBX programming

PBX PROGRAMMING:
Program 05 - 02 - 02 : Set To [ 7 ]     SLT Inter-digit timeout is 60 sec
Program 05 - 06 - 07 : Set To [ 0 ]     Operation for SLT HOLD by  hook flash
Program 05 - 08 - 05 : Set To [ 7 ]     SLT programming digit is 7
Program 05 - 12 - 05 : Set To [ 7 ]     Voice mail leading digit type
              If Extension number is 2 Digits:
                  Internal Call Forward - Busy : 12 + 00 + Called number + 00 + Calling number
                  Internal Call Forward - No Answer : 13 + 00 + Called number + 00 + Calling number
                  Direct Call From Extension : 14 + 00 + Calling number + 00 + Calling number
                  Incoming CO Call Forward - Busy : 22 + 00 + Called number + Trunk number
                  Incoming CO Call Forward - No Answer : 23 + 00 + Called number + Trunk number

                 EVM Programming :
                            SYS _ 6 _ 3 _ [ 2304 ]     No-answer identified code For Incoming co line
                            SYS _ 6 _ 4 _ [ 2204 ]     Busy identified code For Incoming co line
                            ADM _ 5 _ 9928 _ [ 1304 ]     No-answer identified code For Internal Call
                            ADM _ 5 _ 9929 _ [ 1204 ]     Busy identified code For Internal Call
                            ADM _ 5 _ 9920 _ [ 1400 ]     Prefix number of Mailbox ID code

               If Extension number is 3 Digits:
                  Internal Call Forward - Busy : 12 + 0 + Called number + 0 + Calling number
                  Internal Call Forward - No Answer : 13 + 0 + Called number + 0 + Calling number
                  Direct Call From Extension : 14 + 0 + Calling number + 0 + Calling number
                  Incoming CO Call Forward - Busy : 22 + 0 + Called number + Trunk number
                  Incoming CO Call Forward - No Answer : 23 + 0 + Called number + Trunk number

                  EVM Programming :
                            SYS _ 6 _ 3 _ [ 2303 ]     No-answer identified code For Incoming co line
                            SYS _ 6 _ 4 _ [ 2203 ]     Busy identified code For Incoming co line
                            ADM _ 5 _ 9928 _ [ 1303 ]     No-answer identified code For Internal Call
                            ADM _ 5 _ 9929 _ [ 1203 ]     Busy identified code For Internal Call
                            ADM _ 5 _ 9920 _ [ 140 ]     Prefix number of Mailbox ID code

                If Extension number is 4 Digits:
                  Internal Call Forward - Busy : 12 +  Called number  + Calling number
                  Internal Call Forward - No Answer : 13 + Called number  + Calling number
                  Direct Call From Extension : 14 + Calling number  + Calling number
                  Incoming CO Call Forward - Busy : 22 + Called number + Trunk number
                  Incoming CO Call Forward - No Answer : 23  + Called number + Trunk number

                  EVM Programming :
                            SYS _ 6 _ 3 _ [ 2302 ]     No-answer identified code For Incoming co line
                            SYS _ 6 _ 4 _ [ 2202 ]     Busy identified code For Incoming co line
                            ADM _ 5 _ 9928 _ [ 1302 ]     No-answer identified code For Internal Call
                            ADM _ 5 _ 9929 _ [ 1202 ]     Busy identified code For Internal Call

                            ADM _ 5 _ 9920 _ [ 14 ]     Prefix number of Mailbox ID code
Program 43 - [ Port of  EVM ] - 02 : Set To [ 8 ]     Port of  EVM is used as voice mail port
Program 44 - [ Extn of  EVM ] - 03 : Set To [ 1 ]    Disable call split function for Extn of  EVM
Program 46 - [ Extn of  EVM ] - 02 : Set To [ 9 ]    Assign message waiting level to 9 for Extn of  EVM
Program 50 - [ All Extn  ] - 02 : Set To [ 1 ]     Cancel call forward lamp
Program 67 - [ GROUP 01  ]:     Set pilot number of  EVM hunting group
Program 68 - [ GROUP 01  ]:     Assign Extn of EVM  to hunting group 01
Set No Answer and Busy Forward to Pilot number of EVM Hunting Group for All Extn.

¡@

¡@