EVM  PROGRAMMING FOR   LUCENT PROLOGIX

EVM  PROGRAMMING  ITEMEVM  PROGRAMMING  DATA                EXPLANATION
For  op / ext ring duration during
working / closing hrs
SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00]
SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00]
Un-supervisory ringback tone                  
For release after answerSYS _ 5 _ 2 _ [5]ON HOOK
For release w / o waitingSYS _ 5 _ 3 _ [5]ON HOOK
For retrieving call once error toneSYS _ 5 _ 4 _ [3]HOOK FLASH + HOOK FLASH
For retrieving call once on busySYS _ 5 _ 5 _ [3]HOOK FLASH + HOOK FLASH
For retrieving call once no answerSYS _ 5 _ 6 _ [3]HOOK FLASH + HOOK FLASH
For message lamp onSYS _ 5 _ 7 _ [8]Function code + Extn
For message lamp offSYS _ 5 _ 8 _ [8]Function code + Extn
For no-answer identified code
( For External no-answer forward )
SYS _ 6 _ 3 _ [ Function code ]Refer to PBX programming
For code of message lamp onSYS _ 6 _ 6 _ [ Function code ]Refer to PBX programming
For code of message lamp offSYS _ 6 _ 7 _ [ Function code ]Refer to PBX programming
For hook flash timeSYS _ 7 _ 1 _ [By auto detection ]Refer to EVM GUIDE:
How to auto detect hook flash time
For busy tone cycleSYS _ 7 _ 5 _ 1 _ [051]
SYS _ 7 _ 5 _ 2 _ [041]
SYS _ 7 _ 5 _ 3 _ [051]
SYS _ 7 _ 5 _ 4 _ [041]
Data in [ ] is just a reference
Refer to EVM GUIDE :
How to auto detect busy tone cycle
For ringback tone cycleSYS _ 7 _ 6 _ 1 _ [113]
SYS _ 7 _ 6 _ 2 _ [373]
SYS _ 7 _ 6 _ 3 _ [113]
SYS _ 7 _ 6 _ 4 _ [373]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect ringback tone cycle
Waiting time for ID codeADM _ 5 _ 9908 _ [ 0000 ]Delay 0.5 sec before detecting ID code
Prefix number of Mailbox ID codeADM _ 5 _ 9920 _ [Function code]Refer to PBX programming
Suffix  number of Mailbox ID codeADM _ 5 _ 9921 _ [ *1 *1 ]Suffix  number of Mailbox ID code is
# #
For no-answer identified code
( For Internal no-answer forward )
ADM _ 5 _ 9928 _ [Function code]Refer to PBX programming

PBX PROGRAMMING:
Set port of EVM as VMI
Chang system parameters mode code                 page 1
                                        MODE CODE RELATED SYSTEM PARAMETERS
MODE CODE  ( FROM  SWITCH  TO  VMS )
             Direct  inside  Access : Set Function code for Prefix number of Mailbox ID code 
             ( Must be set only in 1 digit)

             Direct Dial Access - Trunk: Delete
             Internal  Coverage: Set Function code for no-answer identified code
             External  Coverage: Set Function code for no-answer identified code

DTMF Duration on (msec): 100  off (msec) : 100  Sending Delay (msec) : 500
Example :
If 8 is set for Direct inside Access code of PBX, then PBX will send out 8 # + Calling number + # # to VMS.
                  EVM Programming must be set as ADM _ 5 _ 9920 _ [ 8*1 ]    
                  EVM Programming must be set as ADM _ 5 _ 9921 _ [ *1 *1 ]
                 

If * 7 is set for Internal Coverage, then PBX will send out  * 7 + # + Calling number + # + Called number + #  to VMS.
                  EVM Programming must be set as ADM _ 5 _ 9928 _ [ **707 ]    Note : If Calling number is in 3 digits
                  EVM Programming must be set as ADM _ 5 _ 9928 _ [ **708 ]    Note : If Calling number is in 4 digits
                  

If * 8 is set for External Coverage, then PBX will send out * 8 + # # + Calling number + # # to VMS. 
                  EVM Programming  must be set as SYS _ 6 _ 3 _ [ **804 ]

Set no-answer forward to Extn of EVM for All Extension.