EVM PROGRAMMING FOR MITEL SX - 200L
EVM PROGRAMMING ITEM | EVM PROGRAMMING DATA | EXPLANATION |
For op / ext ring duration during working / closing hrs | SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00] SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00] | Un-supervisory ringback tone |
For release after answer | SYS _ 5 _ 2 _ [5] | ON HOOK |
For release w / o waiting | SYS _ 5 _ 3 _ [5] | ON HOOK |
For retrieving call once error tone | SYS _ 5 _ 4 _ [1] | HOOK FLASH |
For retrieving call once on busy | SYS _ 5 _ 5 _ [1] | HOOK FLASH |
For retrieving call once no answer | SYS _ 5 _ 6 _ [1] | HOOK FLASH |
For message lamp on | SYS _ 5 _ 7 _ [0] ADM _ 5 _ 9930 _ [342] | Function code + 1 + Extn |
For message lamp off | SYS _ 5 _ 8 _ [*] ADM _ 5 _ 9933 _ [342] | Function code + 2 + Extn |
For directly pick up | SYS _ 5 _ 9 _ [8] | Function code + Extn |
For no-answer identified code | SYS _ 6 _ 3 _ [ Function code ] | Refer to PBX programming |
For busy identified code | SYS _ 6 _ 4 _ [ Function code ] | Refer to PBX programming |
For code of message lamp on | ADM _ 5 _ 9931 _ [ Function code ] ADM _ 5 _ 9932 _ [ 1 ] | Refer to PBX programming |
For code of message lamp off | ADM _ 5 _ 9933 _ [ Function code ] ADM _ 5 _ 9934 _ [ 2 ] | Refer to PBX programming |
For hook flash time | SYS _ 7 _ 1 _ [By auto detection ] | Refer to EVM GUIDE: How to auto detect hook flash time |
For error tone cycle | SYS _ 7 _ 4 _ 1 _ [026] SYS _ 7 _ 4 _ 2 _ [022] SYS _ 7 _ 4 _ 3 _ [026] SYS _ 7 _ 4 _ 4 _ [022] Data in [ ] is just a reference | Refer to EVM GUIDE: How to auto detect error tone cycle |
For busy tone cycle | SYS _ 7 _ 5 _ 1 _ [051] SYS _ 7 _ 5 _ 2 _ [045] SYS _ 7 _ 5 _ 3 _ [051] SYS _ 7 _ 5 _ 4 _ [045] Data in [ ] is just a reference | Refer to EVM GUIDE: How to auto detect busy tone cycle |
For ringback tone cycle | SYS _ 7 _ 6 _ 1 _ [096] SYS _ 7 _ 6 _ 2 _ [280] SYS _ 7 _ 6 _ 3 _ [096] SYS _ 7 _ 6 _ 4 _ [280] Data in [ ] is just a reference | Refer to EVM GUIDE: How to auto detect ringback tone cycle |
For code of directly pick up | ADM _ 5 _ 9907 _ [ Function code ] | Refer to PBX programming |
Waiting time for ID code | ADM _ 5 _ 9908 _ [ 0000 ] | Delay 0.5 sec before detecting ID code |
Prefix number of Mailbox ID code | ADM _ 5 _ 9920 _ [ Function code ] | Refer to PBX programming |
Suffix number of Mailbox ID code | ADM _ 5 _ 9921 _ [ Function code ] | Refer to PBX programming |
PBX PROGRAMMING:
¡@