EVM  PROGRAMMING FOR MITEL SX - 200L

EVM  PROGRAMMING  ITEMEVM  PROGRAMMING  DATA                EXPLANATION
For  op / ext ring duration during
working / closing hrs
SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00]
SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00]
Un-supervisory ringback tone                  
For release after answerSYS _ 5 _ 2 _ [5]ON HOOK
For release w / o waitingSYS _ 5 _ 3 _ [5]ON HOOK
For retrieving call once error toneSYS _ 5 _ 4 _ [1]HOOK FLASH
For retrieving call once on busySYS _ 5 _ 5 _ [1]HOOK FLASH
For retrieving call once no answerSYS _ 5 _ 6 _ [1]HOOK FLASH
For message lamp onSYS _ 5 _ 7 _ [0]
ADM _ 5 _ 9930 _ [342]
Function code + 1 + Extn
For message lamp offSYS _ 5 _ 8 _ [*]
ADM _ 5 _ 9933 _ [342]
Function code + 2 + Extn
For directly pick upSYS _ 5 _ 9 _ [8]Function code + Extn
For no-answer identified codeSYS _ 6 _ 3 _ [ Function code ]Refer to PBX programming
For busy identified codeSYS _ 6 _ 4 _ [ Function code ]Refer to PBX programming
For code of message lamp onADM _ 5 _ 9931 _  [ Function code ]
ADM _ 5 _ 9932 _  [ 1 ]
Refer to PBX programming
For code of message lamp offADM _ 5 _ 9933 _  [ Function code ]
ADM _ 5 _ 9934 _  [ 2 ]
Refer to PBX programming
For hook flash timeSYS _ 7 _ 1 _ [By auto detection ]Refer to EVM GUIDE:
How to auto detect hook flash time
For error tone cycleSYS _ 7 _ 4 _ 1 _ [026]
SYS _ 7 _ 4 _ 2 _ [022]
SYS _ 7 _ 4 _ 3 _ [026]
SYS _ 7 _ 4 _ 4 _ [022]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect error tone cycle
For busy tone cycleSYS _ 7 _ 5 _ 1 _ [051]
SYS _ 7 _ 5 _ 2 _ [045]
SYS _ 7 _ 5 _ 3 _ [051]
SYS _ 7 _ 5 _ 4 _ [045]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect busy tone cycle
For ringback tone cycleSYS _ 7 _ 6 _ 1 _ [096]
SYS _ 7 _ 6 _ 2 _ [280]
SYS _ 7 _ 6 _ 3 _ [096]
SYS _ 7 _ 6 _ 4 _ [280]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect ringback tone cycle
For code of directly pick upADM _ 5 _ 9907 _ [ Function code ]Refer to PBX programming
Waiting time for ID codeADM _ 5 _ 9908 _ [ 0000 ]Delay 0.5 sec before detecting ID code
Prefix number of Mailbox ID codeADM _ 5 _ 9920 _ [ Function code ]Refer to PBX programming
Suffix  number of Mailbox ID codeADM _ 5 _ 9921 _ [ Function code ]Refer to PBX programming

PBX PROGRAMMING:

¡@