EVM PROGRAMMING FOR NEC - M100 / M80
EVM PROGRAMMING ITEM | EVM PROGRAMMING DATA | EXPLANATION |
For op / ext ring duration during working / closing hrs | SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00] SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00] | Un-supervisory ringback tone |
For release after answer | SYS _ 5 _ 2 _ [5] | ON HOOK |
For release w / o waiting | SYS _ 5 _ 3 _ [5] | ON HOOK |
For retrieving call once error tone | SYS _ 5 _ 4 _ [1] | HOOK FLASH |
For retrieving call once on busy | SYS _ 5 _ 5 _ [1] | HOOK FLASH |
For retrieving call once no answer | SYS _ 5 _ 6 _ [1] | HOOK FLASH |
For message lamp on | SYS _ 5 _ 7 _ [8] | Function code + Extn |
For message lamp off | SYS _ 5 _ 8 _ [8] | Function code + Extn |
For no-answer identified code | SYS _ 6 _ 3 _ [ Function code ] | Refer to PBX programming |
For code of message lamp on | SYS _ 6 _ 6 _ [ Function code ] | Refer to PBX programming |
For code of message lamp off | SYS _ 6 _ 7 _ [ Function code ] | Refer to PBX programming |
For hook flash time | SYS _ 7 _ 1 _ [By auto detection ] | Refer to EVM GUIDE: How to auto detect hook flash time |
For error tone cycle | SYS _ 7 _ 4 _ 1 _ [022] SYS _ 7 _ 4 _ 2 _ [022] SYS _ 7 _ 4 _ 3 _ [022] SYS _ 7 _ 4 _ 4 _ [022] Data in [ ] is just a reference | Refer to EVM GUIDE: How to auto detect error tone cycle |
For busy tone cycle | SYS _ 7 _ 5 _ 1 _ [048] SYS _ 7 _ 5 _ 2 _ [045] SYS _ 7 _ 5 _ 3 _ [048] SYS _ 7 _ 5 _ 4 _ [045] Data in [ ] is just a reference | Refer to EVM GUIDE: How to auto detect busy tone cycle |
For ringback tone cycle | SYS _ 7 _ 6 _ 1 _ [096] SYS _ 7 _ 6 _ 2 _ [280] SYS _ 7 _ 6 _ 3 _ [096] SYS _ 7 _ 6 _ 4 _ [280] Data in [ ] is just a reference | Refer to EVM GUIDE: How to auto detect ringback tone cycle |
Waiting time for ID code | ADM _ 5 _ 9908 _ [ 0000 ] | Delay 0.5 sec before detecting ID code |
PBX PROGRAMMING:
Set YY = 03 in COMMAND 13 [ ALL EXTN ] must be set to [ 0 ]
Set YY = 10 in COMMAND 13 [EXTN OF EVM ] must be set to [ 0 ]
Set [ 0 ] in YY = 333 of COMMAND 08
Set NO ANSWER IDENTIFIED CODE ( MUST 2 DIGITS ) for CODE = 3 of YY = 00 of COMMAND 50
Set [ 00 ] for FUNCTION NUMBER = 44 of Y = 0 of COMMAND 41
Set [ 02 ] for FUNCTION NUMBER = 48 of Y = 0 of COMMAND 41
Set [ 07 ] for FUNCTION NUMBER = 49 of Y = 0 of COMMAND 41
Set FUNCTION CODE OF MESSAGE LAMP ON for FUNCTION CODE = 040 of Y = 0 of COMMAND 20
Set FUNCTION CODE OF MESSAGE LAMP OFF for FUNCTION CODE = 041 of Y = 0 of COMMAND 20
Set to STATION HUNTING GROUP for [ EXTN OF EVM ] of Y = 0 of COMMAND 18
Set [ 04 ] for [ TRUNK NUMBER ] of YY = 02 of COMMAND 30
Set [ EXTN OF EVM PORT1 ] for [ TRUNK NUMBER ] of YY = 04 of COMMAND 30