EVM PROGRAMMING FOR NORTHERN NORSTAR-VMI
EVM PROGRAMMING ITEM | EVM PROGRAMMING DATA | EXPLANATION |
For op / ext ring duration during working / closing hrs | SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00] SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00] | Un-supervisory ringback tone |
For dial tone detection | SYS _ 4 _ 5 _ [2] | NO |
For release after answer | SYS _ 5 _ 2 _ [5] | ON HOOK |
For release w / o waiting | SYS _ 5 _ 3 _ [5] | ON HOOK |
For retrieving call once error tone | SYS _ 5 _ 4 _ [2] | HOOK FLASH + Retrieving code |
For retrieving call once on busy | SYS _ 5 _ 5 _ [2] | HOOK FLASH + Retrieving code |
For retrieving call once no answer | SYS _ 5 _ 6 _ [2] | HOOK FLASH + Retrieving code |
For message lamp on | SYS _ 5 _ 7 _ [0] ADM _ 5 _ 9930 _ [132] | HOOK FLASH + Function code + Extn |
For message lamp off | SYS _ 5 _ 8 _ [*] ADM _ 5 _ 9933 _ [132] | HOOK FLASH + Function code + Extn |
For directly pick up | SYS _ 5 _ 9 _ [2] | HOOK FLASH + Function code + Extn |
For call-transferring code | SYS _ 6 _ 1 _ [*70] | Call-transferring code is *70 |
For call-retrieving code | SYS _ 6 _ 2 _ [2] | Call-retrieving code is 2 |
For busy identified code | SYS _ 6 _ 4 _ [ *1602 ] | Refer to VMI programming |
For code of message lamp on | ADM _ 5 _ 9931 _ [ **1] | Function code of message lamp on is * 1 |
For code of message lamp off | ADM _ 5 _ 9933 _ [ *11] | Function code of message lamp off is # 1 |
For hook flash time | SYS _ 7 _ 1 _ [045] | HOOK FLASH TIME 0.45 Sec |
For busy tone cycle | SYS _ 7 _ 5 _ 1 _ [048] SYS _ 7 _ 5 _ 2 _ [045] SYS _ 7 _ 5 _ 3 _ [048] SYS _ 7 _ 5 _ 4 _ [045] Data in [ ] is just a reference | Refer to EVM GUIDE: How to auto detect busy tone cycle |
For ringback tone cycle | SYS _ 7 _ 6 _ 1 _ [189] SYS _ 7 _ 6 _ 2 _ [373] SYS _ 7 _ 6 _ 3 _ [189] SYS _ 7 _ 6 _ 4 _ [373] Data in [ ] is just a reference | Refer to EVM GUIDE: How to auto detect ringback tone cycle |
For code of directly pick up | ADM _ 5 _ 9907 _ [ **76 ] | Function code of directly pick up is *76 |
Waiting time for ID code | ADM _ 5 _ 9908 _ [ 1000 ] | Delay 1 sec before detecting ID code |
For code of disconnect | ADM _ 5 _ 9939 _ [ *10 ] | Refer to VMI programming |
PBX PROGRAMMING:
Programming Item [ Held reminder ] : Y
Programming Item [ Transfer callback ] : 12
Programming Item [ Line assignment ] : Set incoming ring to Extn of EVM
Programming Item [ Intercom keys ] : Set All Extension number to 1
Programming Item [ DND on busy ] : Set All Extension number to YES
Programming Item [ Directed pick up ] : Y
Programming Item [ Forward on busy ] : Set All Extension number forwarded to Extn of EVM Port 1
Programming Item [ Forward on busy ] : Set Extn of EVM Port 1 forwarded to Extn of EVM Port 2
Programming Item [ Forward on busy ] : Set Extn of EVM Port 2 forwarded to Extn of EVM Port 3
Programming Item [ Forward on busy ] : Set Extn of EVM Port 3 forwarded to Extn of EVM Port 4
VMI Programming :
Procedures of Determining the VMI Intercom Number :
1. Press [ Feature ] + [ 900 ], the display will show "VMI Admin"
2. Press [ NEXT ], the display will show "DN1 Number"
3. Press [ NEXT ], the display will show "DN2 Number"
4. Press [ NEXT ], the display will show "Feature Table"
5. Press [ SHOW ], the display will show "Send Msg L*1" ( Function code of message lamp on is * 1 )
6. Press [ NEXT ], the display will show "Cncl Msg L#1" ( Function code of message lamp on is # 1 )
7. Press [ NEXT ], the display will show "Transfer L*70" ( Call-transferring code is *70 )
8. Press [ NEXT ], the display will show "Prefix"
9. Press [ CHANGE ], enter #6 ( For example, Forward ID code is #6)
10. Press [ NEXT ], the display will show "Discon"
11. Press [ CHANGE ], enter #0 ( For example, Disconnect code is #0)