EVM PROGRAMMING ITEM | EVM PROGRAMMING DATA | EXPLANATION |
For op / ext ring duration during working / closing hrs | SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00] SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00] | Un-supervisory ringback tone |
For release after answer | SYS _ 5 _ 2 _ [5] | ON HOOK |
For release w / o waiting | SYS _ 5 _ 3 _ [5] | ON HOOK |
For retrieving call once error tone | SYS _ 5 _ 4 _ [1] | HOOK FLASH |
For retrieving call once on busy | SYS _ 5 _ 5 _ [1] | HOOK FLASH |
For retrieving call once no answer | SYS _ 5 _ 6 _ [1] | HOOK FLASH |
For message lamp on | RS - 232 Protocol | Refer to RS - 232 programming |
For message lamp off | RS - 232 Protocol | Refer to RS - 232 programming |
For directly pick up | SYS _ 5 _ 9 _ [8] | Function code + Extn |
For code of message lamp on | RS - 232 Protocol | Refer to RS - 232 programming |
For code of message lamp off | RS - 232 Protocol | Refer to RS - 232 programming |
For hook flash time | SYS _ 7 _ 1 _ [ By auto detection ] | Refer to EVM GUIDE: How to auto detect hook flash time |
For error tone cycle | SYS _ 7 _ 4 _ 1 _ [026] SYS _ 7 _ 4 _ 2 _ [019] SYS _ 7 _ 4 _ 3 _ [026] SYS _ 7 _ 4 _ 4 _ [019] | Refer to EVM GUIDE: How to auto detect error tone cycle |
For busy tone cycle | SYS _ 7 _ 5 _ 1 _ [048] SYS _ 7 _ 5 _ 2 _ [045] SYS _ 7 _ 5 _ 3 _ [048] SYS _ 7 _ 5 _ 4 _ [045] | Refer to EVM GUIDE: How to auto detect busy tone cycle |
For ringback tone cycle | SYS _ 7 _ 6 _ 1 _ [196] SYS _ 7 _ 6 _ 2 _ [370] SYS _ 7 _ 6 _ 3 _ [196] SYS _ 7 _ 6 _ 4 _ [370] | Refer to EVM GUIDE: How to auto detect ringback tone cycle |
For code of directly pick up | ADM _ 5 _ 9907 _ [ Function code ] | Refer to PBX programming |
PBX RS - 232 PROTOCOL:
Message lamp on protocol : SE ST XXX MW ON CR XXX : Extension number
Message lamp off protocol : SE ST XXX MW OF CR XXX : Extension number
EVM RS - 232 PROGRAMMING:
EVM PROGRAMMING DATA | EVM RESPOND DATA | EXPLANATION |
ADM _ 5 _ 9970 _ [ 5345 ] | EVM Responds [ 5345 ] | Set EVM to send out "SE" |
ADM _ 5 _ 9971 _ [ 2053 ] | EVM Responds [ 2053 ] | Set EVM to send out " S" (Space + S) |
ADM _ 5 _ 9972 _ [ 5420 ] | EVM Responds [ 5420 ] | Set EVM to send out "T "(T + Space) |
ADM _ 5 _ 9973 _ [ **0**0 ] | EVM Responds [ *0*0 ] | Set EVM to send out 1st digit and 2nd digit of Extn |
ADM _ 5 _ 9974 _ [ **020 ] | EVM Responds [ *020 ] | Set EVM to send out 3rd digit of Extn and " " (Space) |
ADM _ 5 _ 9975 _ [ 4*257 ] | EVM Responds [ 4A57 ] | Set EVM to send out "MW" |
ADM _ 5 _ 9976 _ [ 20**9 ] | EVM Responds [ 20*9 ] | Set EVM to send out " " (Space) and code of Message lamp on |
ADM _ 5 _ 9977 _ [ **920 ] | EVM Responds [ *920 ] | Set EVM to send out code of Message lamp on and " " (Space) |
ADM _ 5 _ 9978 _ [ 0*2 ] | EVM Responds [ 0A ] | Set EVM to send out "CR" |
ADM _ 5 _ 9963 _ [ 4*04*3 ] | EVM Responds [ 4 ] | Set EVM to send out "ON" for code of Message lamp on |
ADM _ 5 _ 9964 _ [ 4*046 ] | EVM Responds [ 4 ] | Set EVM to send out "OF" for code of Message lamp off |
ADM _ 5 _ 9961 _ [ 01 ] | EVM Responds [ 01 ] | Set EVM to request a Character Echo |
ADM _ 5 _ 9962 _ [ XXPD ] XX : Baud rate 00 = 19200bps 12 = 1200bps 24 = 2400bps 48 = 4800bps 96 = 9600bps P : Parity 0 = NONE 1 = ODD 2 = EVEN D : Data bit 7 = 7bit 8 = 8bit | EVM Responds [ XXPD ] | Set Baud rate ,Parity and Data bit |
CONNECTING EXPLANATION of EVM RS - 232:
9 Pin Connecter 25 Pin Connecter
Signal number | Pin No. | Cable | Pin No. | Signal number |
RXD | 2 | Cable | 2 | TXD |
TXD | 3 | Cable | 3 | RXD |
DTR | 4 | Cable | 6 | DSR |
DSR | 6 | Cable | 20 | DTR |
RTS | 7 | Cable | 5 | CTS |
CTS | 8 | Cable | 4 | RTS |
SG | 5 | Cable | 7 | SG |
DCD | 1 | Cable | 8 | DCD |
RI | 9 | Cable | 22 | RI |