EVM  PROGRAMMING FOR PANASONIC VB-9

EVM  PROGRAMMING  ITEMEVM  PROGRAMMING  DATA                EXPLANATION
For  op / ext ring duration during
working / closing hrs
SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00]
SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00]
Un-supervisory ringback tone                  
For release after answerSYS _ 5 _ 2 _ [5]ON HOOK
For release w / o waitingSYS _ 5 _ 3 _ [5]ON HOOK
For retrieving call once error toneSYS _ 5 _ 4 _ [1]HOOK FLASH
For retrieving call once on busySYS _ 5 _ 5 _ [1]HOOK FLASH
For retrieving call once no answerSYS _ 5 _ 6 _ [1]HOOK FLASH
For message lamp onNoneFunction not support by PBX
For message lamp offNoneFunction not support by PBX
For directly pick upSYS _ 5 _ 8 _ [8]Function code + Extn
For no-answer identified codeNoneFunction not support by PBX
For code of message lamp onNoneFunction not support by PBX
For code of message lamp offNoneFunction not support by PBX
For hook flash timeSYS _ 7 _ 1 _ [By auto detection ]Refer to EVM GUIDE:
How to auto detect hook flash time
For busy tone cycleSYS _ 7 _ 5 _ 1 _ [048]
SYS _ 7 _ 5 _ 2 _ [045]
SYS _ 7 _ 5 _ 3 _ [048]
SYS _ 7 _ 5 _ 4 _ [045]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect busy tone cycle
For ringback tone cycleSYS _ 7 _ 6 _ 1 _ [096]
SYS _ 7 _ 6 _ 2 _ [186]
SYS _ 7 _ 6 _ 3 _ [096]
SYS _ 7 _ 6 _ 4 _ [186]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect ringback tone cycle
For code of directly pick upADM _ 5 _ 9907 _ [ 7** ]Function code of directly pick up is
7*  ( PBX Default )

PBX PROGRAMMING:
Programming Mode [1]  Item [ 0801 ]:  Set  [1]
Programming Mode [1]  Item [ 0802 ]:  Set  [0]