EVM  PROGRAMMING FOR PHILIPS SOPHO SERIES

EVM  PROGRAMMING  ITEMEVM  PROGRAMMING  DATA                EXPLANATION
For  op / ext ring duration during
working / closing hrs
SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00]
SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00]
Un-supervisory ringback tone                  
For dial tone detectionSYS _ 4 _ 5 _ [1]Detection dial tone
For release after answerSYS _ 5 _ 2 _ [5]ON HOOK
For release w / o waitingSYS _ 5 _ 3 _ [5]ON HOOK
For retrieving call once error toneSYS _ 5 _ 4 _ [1]HOOK FLASH
For retrieving call once on busySYS _ 5 _ 5 _ [1]HOOK FLASH
For retrieving call once no answerSYS _ 5 _ 6 _ [1]HOOK FLASH
For message lamp onSYS _ 5 _ 7 _ [8]Function code + Extn
For message lamp offSYS _ 5 _ 8 _ [8]Function code + Extn
For directly pick upSYS _ 5 _ 9 _ [8]Function code + Extn
For no-answer identified code
( For no-answer forward )
SYS _ 6 _ 3 _ [ 20*20 ]No-answer identified code is
2 + other number + A + Extn + C
For busy identified code
( For busy tone )
SYS _ 6 _ 4 _ [ 10*20 ]Busy identified code is
1 + other number + A + Extn + C
For code of message lamp onSYS _ 6 _ 6 _ [ *1**8 ]Function code of message lamp on is
#*8 ( PBX Default )
For code of message lamp offSYS _ 6 _ 7 _ [ *1*18 ]Function code of message lamp off is
##8 ( PBX Default )
For hook flash timeSYS _ 7 _ 1 _ [By auto detection ]Refer to EVM GUIDE:
How to auto detect hook flash time
For busy tone cycleSYS _ 7 _ 5 _ 1 _ [048]
SYS _ 7 _ 5 _ 2 _ [045]
SYS _ 7 _ 5 _ 3 _ [048]
SYS _ 7 _ 5 _ 4 _ [045]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect busy tone cycle
For ringback tone cycleSYS _ 7 _ 6 _ 1 _ [096]
SYS _ 7 _ 6 _ 2 _ [186]
SYS _ 7 _ 6 _ 3 _ [096]
SYS _ 7 _ 6 _ 4 _ [186]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect ringback tone cycle
For code of directly pick upADM _ 5 _ 9907 _ [ Function code ]Refer to PBX Programming
Waiting time for ID codeADM _ 5 _ 9908 _ [ 2000 ]Delay 2 sec before detecting ID code
Prefix number of Mailbox ID codeADM _ 5 _ 9920 _ [ 01 ]Mailbox ID code is :
01+Calling Extn+A+Called Extn+C
Suffix number of Mailbox ID codeADM _ 5 _ 9921 _ [ *1*100 ]Suffix number of Mailbox ID code is
##00 ( mean to ignore )

PBX PROGRAMMING: