EVM  PROGRAMMING FOR TECOM SD - 100 / SD - 300

EVM  PROGRAMMING  ITEMEVM  PROGRAMMING  DATA                EXPLANATION
For  op / ext ring duration during
working / closing hrs
SYS _ 2 _ 2 _ [00],SYS _ 2 _ 3 _ [00]
SYS _ 2 _ 4 _ [00],SYS _ 2 _ 5 _ [00]
Un-supervisory ringback tone                  
For release after answerSYS _ 5 _ 2 _ [5]ON HOOK
For release w / o waitingSYS _ 5 _ 3 _ [5]ON HOOK
For retrieving call once error toneSYS _ 5 _ 4 _ [1]HOOK FLASH
For retrieving call once on busySYS _ 5 _ 5 _ [1]HOOK FLASH
For retrieving call once no answerSYS _ 5 _ 6 _ [1]HOOK FLASH
For message lamp onSYS _ 5 _ 7 _ [8]Extn + Function code
For message lamp offSYS _ 5 _ 8 _ [8]Function code + Extn
For directly pick upSYS _ 5 _ 9 _ [8]Function code + Extn
For no-answer identified code
( For no-answer forward )
SYS _ 6 _ 3 _ [ Function code ]Refer to PBX Programming
For busy identified code
( For busy forward  )
SYS _ 6 _ 4 _ [ Function code ]Refer to PBX Programming
For code of message lamp onSYS _ 6 _ 6 _ [ *196 ]Function code of message lamp on is
#96
For code of message lamp offSYS _ 6 _ 7 _ [ *1**96 ]Function code of message lamp off is
#*96
For hook flash timeSYS _ 7 _ 1 _ [By auto detection ]Refer to EVM GUIDE:
How to auto detect hook flash time
For error tone cycleSYS _ 7 _ 4 _ 1 _ [022]
SYS _ 7 _ 4 _ 2 _ [019]
SYS _ 7 _ 4 _ 3 _ [022]
SYS _ 7 _ 4 _ 4 _ [019]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect error tone cycle
For busy tone cycleSYS _ 7 _ 5 _ 1 _ [048]
SYS _ 7 _ 5 _ 2 _ [045]
SYS _ 7 _ 5 _ 3 _ [048]
SYS _ 7 _ 5 _ 4 _ [045]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect busy tone cycle
For ringback tone cycleSYS _ 7 _ 6 _ 1 _ [099]
SYS _ 7 _ 6 _ 2 _ [283]
SYS _ 7 _ 6 _ 3 _ [099]
SYS _ 7 _ 6 _ 4 _ [283]
Data in [ ] is just a reference
Refer to EVM GUIDE:
How to auto detect ringback tone cycle
For code of directly pick upADM _ 5 _ 9907 _ [ *153 ]Function code of directly pick up is
#53
Waiting time for ID codeADM _ 5 _ 9908 _ [ 2000 ]Delay 2 sec before detecting ID code
Prefix number of Mailbox ID codeADM _ 5 _ 9920 _ [ Function cod ]Refer to PBX Programming

PBX PROGRAMMING:
Programming Item [ 6.CONTROL ]:
                            1. EXT HUNT GROUP  
                            2. HUNT GROUP : enter 1  
                            3. MEMBER 01: enter Extn of  EVM PORT 1
                            4. MEMBER 02 : enter Extn of  EVM PORT 2 
                            5. MEMBER 03 : Extn of  EVM PORT 3 
                            6. MEMBER 04 : enter Extn of  EVM PORT 4

Programming Item [ 6.CONTROL ]:
                            1. VOICE MAIL 
                            2. VM HUNT GROUP : enter 1 
                            3. PREFIX CODE 
                            4. ICM / VM:  set to Prefix number of Mailbox ID code 
                            5. BUSY FWD: set to busy identified code
                            6. NO_ANS FWD: set to no-answer identified code
                            Example :
                                          If ICM / VM is set to [ 40 ] ,  then set EVM Programming ADM _ 5 _ 9920 _ [ 40 ]
                                          If BUSY FWD is set to [ 41 ], then set EVM Programming SYS _ 6 _ 4 _ [ 4102 ]
                                          If NO_ANS FWD is set to [ 42 ], then set  EVM Programming SYS _ 6 _ 3 _ [ 4202 ]

Programming Item [ 2.TRUNK LINE ]:
                             1. SHOW TRUNK: enter TRUNK LINE NUMBER
                             2. HUNT GROUP ANS :  enter 1
                         
OPERATOR PROFRAMMING :
1. press [ FUNCTION KEY ] + # + 0 
2. CHK PSWD : ENTER PASSWORD
3. CFW AUIX LAMP
4. ALL EXT SET TO N
                           
SET NO ANSWER AND BUSY FORWARD TO [ 82 ] FOR ALL EXTS